SpECcoat Firesafe Facade

Fire-rated moisture barrier for flexible facade protection.

SpECcoat Firesafe Facade is a high-performance, two-component polymer modified cementitious coating designed to create a flexible, fire-resistant moisture barrier for building facades. It can be easily applied using a trowel, brush, or spray, ensuring effective moisture exclusion while allowing breathability. This product is ideal for areas requiring enhanced fire safety without compromising structural integrity.
Its unique formulation provides excellent adhesion and flexibility, making it suitable for various facade applications.

Product Videos

Technical Details

SpECcoat Firesafe Facade is ideal for various applications where moisture protection and fire resistance are critical. Typical uses include:
– Building facades requiring moisture exclusion
– Areas exposed to high levels of water exposure
– Projects that demand compliance with fire safety regulations
– Surfaces needing breathable yet waterproof barriers
– Restoration of existing facades with fire safety concerns
– Environments with extreme temperature fluctuations
SpECcoat Firesafe Facade offers a range of advantages that make it a superior choice for building facade applications. Its unique formulation and performance characteristics ensure both safety and durability in diverse environments. Key advantages include:
– Fire resistant
– High bond strength to concrete and masonry
– Excellent flexibility
– Long pot life even at high temperatures

The technical information for SpECcoat Firesafe Facade provides essential details that ensure proper application and performance in various environments:

Pot life @ 25°C 45 mins
Colour Grey
Minimum application temperature 5°C
Touch dry 2 – 5 hours
Full cure 28 days
Flame Spread Index (FSI) 10 Class A
Smoke Developed Index (SDI) 40 Class A
Water Vapour Transmission 0.02 g/m²/hour

The application process for SpECcoat Firesafe Facade is crucial to achieve optimal performance and durability. Follow the guidelines below to ensure proper installation:

Preparation:
It is essential that adequate preparation is carried out prior to the application of SpECcoat Firesafe Facade. The substrate must be clean and completely free from contaminants, including grease, oil, and loose material. Any repairs to the substrate should be carried out using SpECbuild cementitious repair mortars. Dampening the Substrate:
The prepared substrate should be dampened using a fine water spray. Care should be taken with porous substrates, as more extensive pre-soaking will be required. Any free water on the surface should be removed immediately prior to applying SpECcoat Firesafe Facade. Application Method:
While the substrate is damp but free from standing water, apply the mixed product by medium hard short bristle brush, trowel, or roller. Check that the first coat is at a wet film thickness of 0.40 – 0.60mm. The product should always be finished in one direction and never applied at a higher thickness in one coat. Second Coat Application:
The second coat should be applied as soon as the first coat is dry, normally after a minimum of 3 hours at 25°C and longer at lower temperatures. This second coat should be finished in one direction, 90° to the first coat, at a wet film thickness of 0.40 – 0.6mm. Total Thickness:
The total thickness should be 1.0 – 1.20mm. Curing:
Normally, SpECcoat Firesafe Facade does not need to be cured. However, in hot conditions where there exists high air movement, protection against premature drying is essential.

SpECcoat Firesafe Facade is supplied in a convenient packaging system designed for ease of use and application:

  • 15kg two-part packs

A complete mixed pack will cover approximately 15m² at 0.5mm wet film thickness per coat, depending on the substrate profile.

For information regarding the warranty of SpECcoat Firesafe Facade, please contact our team at SMCC. We will be happy to assist you with any questions or concerns you may have.

You can reach us using any of the contact methods available on this page.

Product FAQ

SpECcoat Firesafe Facade is suitable for concrete, masonry, and existing facades requiring moisture protection and fire resistance.
SpECcoat Firesafe Facade is applied by first ensuring the substrate is clean and damp. The mixed product is then applied using a medium hard brush, trowel, or roller at a wet film thickness of 0.40 – 0.60mm. After the first coat dries, which typically takes 3 hours at 25°C, a second coat is applied at the same thickness, perpendicular to the first coat, achieving a total thickness of 1.0 – 1.20mm.
SpECcoat Firesafe Facade has a Flame Spread Index (FSI) of 10 Class A and a Smoke Developed Index (SDI) of 40 Class A, indicating excellent fire resistance and low smoke production.
A complete mixed pack of SpECcoat Firesafe Facade covers approximately 15m² at a wet film thickness of 0.5mm per coat, depending on the substrate profile.
SpECcoat Firesafe Facade is available in grey.
SpECcoat Firesafe Facade offers several key advantages: it is fire resistant, provides high bond strength to concrete and masonry, exhibits excellent flexibility, and has a long pot life even at high temperatures.

SMCC AI

Ask it Anything!

Related Products

Get a call back

For inquiries about SpECcoat Firesafe Facade, including technical details and project specifications, please fill out the contact form. Our expert team is ready to assist you with solutions tailored to your construction needs, ensuring optimal performance and safety for your facades.

Documents

Download TDS

Email Us

info@smcc.com.sa

Send Us

WhatsApp Message

Need Help?

0543514030

SpECcoat Firesafe Facade