Property | Test Method | Value |
---|---|---|
Water Absorption ISAT | BS EN 1881-208 | 10 minutes: 0.025 ml/m²/sec 30 minutes: nil |
Setting Time | BS EN 196-3 | Initial: 2.0 hours Final: 4.0 hours |
Linear Shrinkage | ASTM C531-00 | 7 days: 0.060% |
Coefficient of Thermal Expansion | – | 5 x 10-6 K |
Compressive Strength | BS 6319-2 | 1 day: 25±5 N/mm² 3 days: 40±5 N/mm² 7 days: 55±5 N/mm² 28 days: 70±5 N/mm² |
Flexural Strength | BS 6319-3 | 28 days: 10±2 N/mm² |
Tensile Strength | BS 6319-7 | 28 days: 3 N/mm² |