SpECtop ARE300

Solvent-based epoxy for durable, chemical-resistant flooring.

SpECtop ARE300 is a two-component solvent-based epoxy resin coating, designed to create a hard and durable surface that withstands heavy traffic and rigorous conditions.
It is easy to clean, making it suitable for various industrial settings where hygiene is crucial, ensuring a maintenance-free life while providing excellent chemical resistance. Ideal for applications requiring a robust floor coating solution.

Product Videos

Technical Details

SpECtop ARE300 is suitable for various applications where heavy traffic and chemical resistance are critical. Typical uses include:
– Dairies
– Beverage plants
– Showrooms
– Kitchens
– Assembly areas in production units
– Covered car parks
– Aircraft hangers
SpECtop ARE300 offers a range of benefits that make it an ideal choice for industrial flooring solutions. Its unique formulation ensures durability, efficiency, and ease of maintenance, catering to the demanding requirements of various applications.
– Range of colours
– Excellent chemical resistance
– Impermeable surface ensuring ease of cleaning
– Extremely hard wearing enabling long periods between maintenance work
SpECtop ARE300 is engineered for superior performance, showcasing impressive technical specifications that ensure reliability and durability in demanding environments:
Property Value
Tack free time 3 – 5 hours at 20°C
Pot life 3 hours at 20°C
Time between coats 16 – 24 hours at 20°C
Initial hardness 24 hours
Full cure 7 days at 20°C
Typical system thickness 300μm (dft)
Application temperature range Minimum 5°C, Maximum 35°C
Shelf life 12 months when stored in unopened packs between 10 and 30°C
Flashpoint SpECtop ARE300 >60°C, SpECtop Cleaning Fluid >40°C
Application of SpECtop ARE300
Preparation:
SpECtop ARE300 must only be applied to adequately prepared substrates, which should be clean and dry to ensure high adhesion properties. The floor should be at least 28 days old prior to application, and the retained moisture should be below a reading of 75% on a hygrometer. The surface should then be acid etched or lightly grit blasted to remove laitance on new floors and contamination, such as oil and grease, from older floors.
Mixing:
SpECtop ARE300 is supplied in a two-component kit consisting of a curing agent and a pigmented base component. Both components should be thoroughly stirred prior to mixing to ensure full dispersion of the suspended material. The total contents of the hardener component should be added to the base tin and mixed for a full 3 minutes using a slow-speed electric drill fitted with a mixing paddle.
Application:
The mixed product should be applied using a stiff brush or a lambswool roller, ensuring that the area is covered uniformly while avoiding the formation of areas with a wet film thickness in excess of 250 microns. The final coat may be applied once the first coat has become dry to the touch, typically within 16-24 hours at 20°C.
Slip Resistant Profile:
If a slip-resistant profile is required, the first coat is completely blinded with the chosen grade of SpECtop NS Grains while the coating is still wet. Once the first coat has reached its initial cure (12 hours at 20°C), the excess aggregate should be removed by vacuum from the surface. The top coat is then reapplied by a medium roller to achieve the desired finish.
Equipment Cleaning:
SpECtop ARE300 should be cleaned from tools and equipment immediately after use using SpECtop Cleaning Fluid.
SpECtop ARE300 is available in various packaging formats to suit different project needs:
– SpECtop ARE300 4.5 litres and 15 litres
– SpECtop NS GRAINS 25kg bags
Warranty Information
For detailed warranty information regarding SpECtop ARE300, please contact our team at SMCC using the contact methods available on this page. We are here to assist you with any inquiries you may have.

Product FAQ

SpECtop ARE300 can be applied on adequately prepared concrete substrates, including new and older floors, provided they are clean, dry, and free from contamination.
The curing time for SpECtop ARE300 is 7 days at 20°C.
SpECtop ARE300 exhibits excellent resistance to various chemicals, including acids, alkalis, and oils. It withstands common substances like citric acid, hydrochloric acid, and concentrated bleach, making it ideal for industrial environments where chemical exposure is frequent.
Yes, SpECtop ARE300 can be used outdoors if applied within the recommended temperature range and on adequately prepared surfaces.
Yes, SpECtop ARE300 is designed for high-traffic areas due to its durability and hard-wearing properties.
Yes, SpECtop ARE300 can be used on ramps due to its excellent slip resistance and durability, making it suitable for high-traffic areas. Proper surface preparation is essential to ensure adhesion and performance.